Construction and seismic engineering experts have several essential design pillars to follow to help a building stand securely during an earthquake. The foundation has to be strong, but the building must also withstand erratic movement, geometric fractures and pressures on the structure’s materials.

A multidisciplinary approach is vital for earthquake-resistant design, which is why some constructions survive seismic events, and others crumble.

Structural Ductility and Energy Dissipation

Elastic strength can describe how much pressure a building can endure without becoming permanently damaged, but an earthquake’s forces are too powerful to rely on this metric alone to preserve structures during a disaster.

So, engineers and construction workers need to focus on ductility instead. They do this by choosing materials that are more malleable and absorb energy. Buildings with these properties may remain standing without losing their load-bearing capacity or fracturing.

Professionals can achieve ductile strength in myriad ways, including choosing inherently energy-resistant materials. But for elements such as concrete foundations, designers can use composite materials to impart these characteristics to structures.

Concrete-filled double steel tubular columns with hoops are a well-known example, improving a structure’s strength by up to 25% with improved ductility. Without supplemental systems like hoops, masonry or concrete joints could crack under excessive elastic stress.

Base Isolation and Damping Systems

An earthquake impacts the whole structure, but it compromises the foundation first. Therefore, if experts can decouple the foundation from the rest of the building, it could improve the building’s resilience. Base isolation does this by using flexible elastomeric lead-rubber and pendulum bearings to make the building dynamic against the most forceful points of an earthquake’s impact.

These bearings can combine with supplemental dampers that serve as shock absorbers in earthquake-resistant design. Tuned mass dampers also absorb kinetic energy and dissipate it as heat. This measure, combined with a responsive structure that sways to the largest impacts, will mitigate much of the damage it could cause.

Natural Frequency, Resonance and Shock Response Spectrum (SRS) Matching

SRS is a common method used to determine a building’s resistance to impacts and transient shocks against its natural period and frequency. These reviews determine the maximum displacement, or peak response, the building can handle. Typically, earthquake testing uses 2% critical damping, which affects the building’s resonant response.

Resonance occurs when buildings experience forces and vibrations that match their own frequency, eventually leading to swaying and pressure buildup. If the structure can handle these vibrational patterns efficiently, it could be more likely to withstand an earthquake. Otherwise, it will sway and buckle, leading to collapse.

No case study explores earthquakes better than the events in Mexico City in 1985, when a catastrophic magnitude-8.0 earthquake hit. Around 600 adobe homes were destroyed, while the city’s unique topography became another source of stress. The shockwaves caused damage as they traveled through loose lacustrine sediment, tearing down 400 buildings between five and 15 stories high due to intense resonance, with thousands more structures damaged.

Continuous Load Paths and Diaphragm Rigidity

Floor slabs and foundations manage horizontal inertial forces, requiring an unbroken load path for them to travel through. In many places, vertical loads may be the primary consideration. However, lateral movement may be more crucial for ensuring proper building performance in earthquake-prone areas.

Sometimes, these structures have more features to accommodate this, including:

  • Shear walls
  • Lift cores
  • Bracing
  • Anchors

Other elements can include floor diaphragms, which are horizontal beams that distribute the pressure. These, combined with shear walls and braced frames that resist lateral shear, can provide a comprehensive solution to earthquake forces.

Experts must ensure each component has a strong connection to preserve the load path’s integrity. A poor welding job could jeopardize the strength of the best structural reinforcements. If welding seams rupture, it could cause a localized joint failure, leading to progressive destruction throughout the rest of the building.

Regularity vs. Structural Irregularities

To give a structure an inherently greater chance of surviving seismic events, it should be built with symmetry. Uneven distribution of weight and materials causes an imbalance, leading some parts of the structure to have greater strength or elasticity than others.

While asymmetry is possible, engineers and architects would need to have a different reinforcement strategy for different parts of the building to maintain overall safety. Failure to do so would create concentrated stress points throughout the structure, posing acute threats.

In 1994, a 6.8-magnitude earthquake struck the San Fernando Valley in Los Angeles, with the Northridge community hit hardest. Between 80,000 and 125,000 people were displaced from their homes.

Many structural failures occurred in soft-story buildings, where open or weak lower levels created irregular load paths and made the structures more vulnerable to collapse. Their large, open interior spaces made them more vulnerable to collapse because the buildings’ mass and rigid lateral-resisting elements were unevenly aligned.

Geotechnical Integrity and Soil-Structure Interaction (SSI)

Foundations are crucial to structural stability, but the soil beneath them plays an equally important role. If the substrata are loose and ground shaking further alters soil mechanics during an earthquake, the structure will collapse. Soil moisture may increase the chances of this.

During earthquake shaking, loose, saturated soil can liquefy beneath a heavy building, causing the structure to slide, tilt or settle unevenly. This also leads to SSI, in which stiff structures react to soft ground. These interactions are why the 1964 Niigata earthquake in Japan was so destructive, as liquefaction was one of the primary causes of the coastal area’s extensive damage.

Building for Earthquake Resilience With Seismic Engineering

Overreliance on concrete foundations and immense structural weight may not produce a building that will withstand geoseismic movement, especially as natural disasters become more intense and damaging. Engineers and architects are looking at buildings more holistically, implementing earthquake-resilient features from the drafting stages.

These techniques combine materials science, climate-conscious construction and innovative architecture to make buildings that can withstand and recover from extreme events.

Credit for Image: Photo by Ricardo Gomez Angel on Unsplash